Learn 132kV Line Protection Setting and Calculations

Focused View

Elite Engineering

1:48:13

22 View
  • 1. Introduction.mp4
    11:25
  • 1. Collecting Data of line.mp4
    10:01
  • 1. Line Impedance and line angle.mp4
    04:29
  • 1. Setting calculations of Zone 1.mp4
    06:59
  • 1. How to set Zone 2 Reach.mp4
    06:03
  • 1. How to set Zone 3 Reach.mp4
    02:31
  • 1. Collection of Line Data.mp4
    04:06
  • 1. Zero Sequence Impedance.mp4
    04:01
  • 1. CT, VT ratios and transformation factor.mp4
    07:23
  • 1. Calculate secondary impedance of line under protection.mp4
    03:31
  • 1. Selection of Relay Characteristics Mho or Quad.mp4
    04:39
  • 1. Calculate Zero Sequence compensation factor.mp4
    07:35
  • 1. Zone 1 Calculations.mp4
    05:20
  • 1. Zone 2 and 3 calculations.mp4
    03:00
  • 1. Non Homogenous correction angle.mp4
    02:44
  • 1. Load Encroachment Settings.mp4
    08:02
  • 1. Power Swing Blocking.mp4
    07:40
  • 1. SOTF and Loss of Potential.mp4
    08:44
  • Description


    Lear 132kV Distance Protection Relay Settings for SEL411 Relays, Electrical Power Engineering

    What You'll Learn?


    • Real Relay settings example
    • Basic concepts of Distance Protection Relays
    • What are zones & how to set them
    • Zone calculations
    • What is difference between primary and secondary values
    • Transformation factor
    • Selectivity
    • Time settings of zone
    • Loss of potential, VT MCB trip & distance blocking
    • Load encroachment
    • Power swing blocking, out of step tripping, stable and unstable power swing
    • Switch on to fault, seal in time

    Who is this for?


  • Any one eager to learn
  • What You Need to Know?


  • No prior experience is needed.
  • More details


    Description

    Dear All,


    Distance protection relay is one of the most important and artistic. A distance relay is a type of protection relay most often used for transmission line protection. Distance relays measure the impedance from the installation side to the fault location and operates in response to changes in the ratio of measured current and voltage.

    Distance protection schemes are commonly employed for providing the primary or main protection and backup protection for AC transmission line and distribution line against three-phase faults, phase-to-phase faults, and phase-to-ground faults.

    I have field experience of 18 years and I have prepare this course based on practical experience. Following topics are covered in this course.


    • Single Line Diagram of Substation

      • Course will start with explanation of single line diagram of substation

      • Understand substation configuration

    • Getting required data of transmission line

      • How line impedance is gathered

    • Selection of adjacent line, shortest & longest

    • How to set zone reaches for Z1,Z2 & Z3

    • Current and voltage transformers

    • Primary and secondary values

    • What is transformation factor & how to calculate it

    • Positive and zero sequence impedances

    • Phase to ground compensation factor

    • How to calculate Ko for composite lines

    • What is Line angle and load angle

    • What is line impedance

    • How to select relay characteristics Mho or Quad

    • How to do Zone 1, 2 & 3 calculations

    • How to set non-homogeneous angle

    • What is load encroachment and how to avoid it

    • Power swing blocking

    • Out of step tripping

    • Stable and unstable power swing

    • Switch on to fault

    • Seal in time

    • Loss of potential

    Best Regards

    Who this course is for:

    • Any one eager to learn

    User Reviews
    Rating
    0
    0
    0
    0
    0
    average 0
    Total votes0
    Focused display
    Elite Engineering
    Elite Engineering
    Instructor's Courses
    Elite Engineering is an engineering academy that is formed by professional with experience in the field of electrical, substation, power transformers, power plants, transmission lines, project management, errection, installation & testing & commissioning.Trainers have up to 20 years of field experience at various voltage levels starting from low voltage, 11kV, 33kV, 66kV, 132kV, 220kV, 380kV, 500kV AC system & 660kV HVDC voltage level. Experienced gain while serving in Middle East, EU, South Asia while serving several companies like Saudi Electricity, Saudi Aramco, SABIC, Marafiq, Siemens, ABB, Alstom, AREVA.Excellent knowledge and delivering the theory and practical concept with such an ease.  Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.
    Students take courses primarily to improve job-related skills.Some courses generate credit toward technical certification. Udemy has made a special effort to attract corporate trainers seeking to create coursework for employees of their company.
    • language english
    • Training sessions 18
    • duration 1:48:13
    • English subtitles has
    • Release Date 2024/04/29